Service difficulty report · Power Supply · Airbus A319112

Difficulty date
May 17, 2021
Submitted
May 17, 2021
Operation
Air carrier
Aircraft
N757UW
Make and model
Airbus A319112
Aircraft serial
1342
Aircraft time
49,621 hours, 34,230 cycles
Part
Power Supply
Condition
Inoperative
Location
Emergency Lights
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS NOTE GROUNDED: RIGHT OVERWING EMERGENCY LIGHT TEST FAILED WHILE PERFORMING JOB CARD 26L00025010 R1 SLIDE REPLACEMENT. REMOVED AND REPLACED RIGHT EMERGENCY POWER SUPPLY UNIT BATTERY IAW AMM 33-51-38.