What was found
AIRCRAFT WAS NOT GROUNDED: FUEL CENTER TANK PUMP 1 LOW PRESSURE. **SUPPLEMENTAL REPORT FOR AALA202108168408: MAINTENANCE PERFORMED GENERAL VISUAL INSPECTION OF THE #1 CENTER TANK PUSH BUTTON SWITCH 33QA AND FOUND SWITCH UNSECURED & LOOSE RESULTING IN THE SWITCH BEING REPLACED PER ELECTRICAL STANDARD PRACTICES 2045110101. ALSO REPLACED INHIBIT RELAY 49QA (AALA202108193063) PER ELECTRICAL STANDARD PRACTICES 20-46-50. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED PER AMM 29-21-00-720-001 AS WELL AS TRANSFERRED FUEL TO AND FROM CENTER TANK USING #1 PUMP WITH NO FAULTS NOTED PER AMM 28-21-00-710-001. ** (CLOSED)