What was found
AIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL NEAR FASTENER HOLES BETWEEN STA 500 AND STA 500A AT RBL 26, MEASURING L=1.0 IN, W=1.0 IN, D=0.031 IN. ACCOMPLISHED PERMANENT REINFORCING PLUG REPAIR IAW EA330774.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: CORROSION OF TRANSITION PANEL NEAR FASTENER HOLES BETWEEN STA 500 AND STA 500A AT RBL 26, MEASURING L=1.0 IN, W=1.0 IN, D=0.031 IN. ACCOMPLISHED PERMANENT REINFORCING PLUG REPAIR IAW EA330774.