What was found
AIRCRAFT WAS GROUNDED: ENGINE # 1 ECAM MESSAGES FOR COMPRESSOR VANE FAULT, ENGINE 1 FAIL AND EGT EXCEEDED ENGINE SHUTDOWN IN FLIGHT. NO EMERGENCY WAS DECLARED, AND THE AIRCRAFT LANDED AT PHX SAFELY WITHOUT FURTHER INCIDENT. A REVIEW OF THE DFDR DATA NOTED THAT THE ENGINE ENCOUNTERED A STALL NEAR THE TOP OF THE CLIMB AND ENGINE PARAMETERS SHOW THAT N1 WENT SUB IDLE AND TRIGGERED A STALL ALERT. SHORTLY AFTER THE PILOTS PULLED THE TLA BACK ON THE ENGINE AND ABOUT 1 MINUTE LATER CLOSED THE FUEL VALVE. EGT ROSE TO 713 FOR 21 SECONDS RESULTING IN AN AREA B EXCEEDANCE. **ORIGINAL SUPPLEMENTAL REPORT WAS AALA202110081724** MAINTENANCE ACCOMPLISHED A BORESCOPE INSPECTION OF THE #1 ENGINE WITH NO DEFECTS BEING NOTED. REPLACED #1 ENGINE VARIABLE STATOR VANE ACTUATOR PER TC 26T40075005 AND REPLACED #1 ENGINE LOW PRESSURE / HIGH PRESSURE FUEL PUMP PER AMM 73-12-41-0401-13 (AALA202110131345). A SATISFACTORY LEAK / OPERATIONAL CHECK WAS ACCOMPLISHED.