Service difficulty report · Regulator Valve · Airbus A319112

Difficulty date
October 25, 2021
Submitted
October 27, 2021
Operation
Air carrier
Aircraft
N711UW
Make and model
Airbus A319112
Aircraft serial
1033
Aircraft time
60,017 hours, 35,024 cycles
Part
Regulator Valve
Part number
6774E010000
Part serial
0568
Condition
Faulty
Location
Zone 400 - Nac/P
Part time
63,317 hours, 29,149 cycles
Component
Engine · CFM565B
Component part number
CFM565BTIQEC319
Stage of operation
CR
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: ICING RESTRICTION AND ENGINE 2 BLEED FAULT AT 36000 FT, QRH RESET INEFFECTIVE; FLIGHT DIVERTED TO DFW AND LANDED WITHOUT INCIDENT. REPLACED BLEED PRESSURE REGULATOR VALVE WITH SERVICEABLE UNIT IAW AMM 36-11-52-400-042-A6, LEAK AND OPS CHECK GOOD.

More about the Airbus A319-112