What was found
AIRCRAFT IN BASE MAINTENANCE: CORROSION, MEASURING L=1.666 IN, W=0.988 IN, D=0.025 IN, ON AFT GALLEY AREA FLOOR BEAM LOCATED BETWEEN FR 64 TO FR 66 AT -Y765. REPLACED FLOOR BEAM PER SRM 51-72-11-911-001, SRM 51-42-11-801, AND DWG D53472000, D53472816.