What was found
CORROSION, MEASURING L=2.5 IN, W=1.00 IN, D=0.01 IN, ON AFT CARGO AREA LEFT HAND TRANSITION PANEL LOCATED BETWEEN BS 767 AND BS 787 AT S25L. REPLACED PANEL PER SRM 53-00-53-2R-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION, MEASURING L=2.5 IN, W=1.00 IN, D=0.01 IN, ON AFT CARGO AREA LEFT HAND TRANSITION PANEL LOCATED BETWEEN BS 767 AND BS 787 AT S25L. REPLACED PANEL PER SRM 53-00-53-2R-5.