What was found
AIRCRAFT WAS GROUNDED: AFTER AIRCRAFT BOARDING THE JET BRIDGE WAS PULLED AWAY THE GROUND PERSONNEL REPORT FLAME IMINATING FROM APU AND LARGE AMOUNT OF SMOKE. THE APU AUTO-SHUTDOWN BEFORE THE CREW COULD MANUALLY SHUT IT DOWN. MAINTENANCE FOUND THE APU FUEL LOW PRESSURE SHUTOFF VALVE ACTUATOR WAS STUCK OPEN AND REPLACED IT PER AMM 28-29-51-400-001. (AALA202111091189) A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED. MAINTENANCE INSPECTED THE APU EXHAUST AND AFT TURBINE BEARING AREA FOR OIL LEAKS OR PUDDLING WITH NO ISSUES NOTED. THEY FOUND THE LOWER AFT SCAVENGE LINE O-RING LEAKING AND REPLACED IT PER AMM 49-91-53-400. (AALA202111090515) **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)