Service difficulty report · Power Supply · Airbus A300*

Difficulty date
December 1, 2021
Submitted
December 2, 2021
Operation
Air carrier
Aircraft
N913US
Make and model
Airbus A300*
Aircraft serial
6255
Aircraft time
23,597 hours, 9,201 cycles
Part
Power Supply
Condition
Failed
Location
Zone 200 - Fuse
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT IN BASE MAINTENANCE: EMERGENCY OPERATIONAL LIGHT TEST 33-51-00-710-001-A FAILS. REMOVED CEILING PANELS 231JC AND 251KC AND DISCONNECTED THE EXIT LIGHT SIGNS PER AIRBUS A321 AMM 25-23-41-400-001-A. PERFORMED THE EMERGENCY POWER SYSTEM UNIT RESET PROCEDURE PER AIRBUS A321 AMM 33-51-38-400-001-A. RECONNECTED THE EMERGENCY LIGHT SIGNS AND REINSTALLED THE CEILING LIGHT PANELS PER AIRBUS AMM 25-23-41-400-001-A.