What was found
AIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT TEST STEP 2(10) OF JOB CARD 26C20033001 FAILS TO BRING ON ALL EMERGENCY LIGHTS ON. JUST HALF ILLUMINATE. REMOVED AND REPLACED AFT EMERGENCY POWER SUPPLY UNIT BATTERY PER AMM 33-51-38.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT TEST STEP 2(10) OF JOB CARD 26C20033001 FAILS TO BRING ON ALL EMERGENCY LIGHTS ON. JUST HALF ILLUMINATE. REMOVED AND REPLACED AFT EMERGENCY POWER SUPPLY UNIT BATTERY PER AMM 33-51-38.