What was found
AIRCRAFT WAS GROUNDED: FLAPS WOULD NOT EXTEND AND YAW DAMPER FAILED IN DESCENT, FLAPS EXTENDED ELECTRICALLY PER QRH PROCEDURE TO 15 DEGREES. REPLACED #8 FLAP SKEW SENSOR WITH SERVICEABLE UNIT IAW AMM 27-59-01, OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT WAS GROUNDED: FLAPS WOULD NOT EXTEND AND YAW DAMPER FAILED IN DESCENT, FLAPS EXTENDED ELECTRICALLY PER QRH PROCEDURE TO 15 DEGREES. REPLACED #8 FLAP SKEW SENSOR WITH SERVICEABLE UNIT IAW AMM 27-59-01, OPS CHECK GOOD.