Service difficulty report · Cooling Fan · Airbus A320214

Difficulty date
March 2, 2022
Submitted
March 4, 2022
Operation
Air carrier
Aircraft
N119US
Make and model
Airbus A320214
Aircraft serial
1268
Aircraft time
62,782 hours, 30,752 cycles
Part
Cooling Fan
Part number
361614011
Part serial
P4491
Condition
Leaking
Location
Zone 100 - Fuse
Part time
4,606 hours, 2,818 cycles
Component
Apu · Honeywell · 1319A
Component part number
38007081
Stage of operation
TO
How discovered
O
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: ODOR CONSISTENT THROUGH FLIGHT WITH PACKS ON ENGINE AND APU. MAINTENANCE FOUND APU OIL COOLING FAN LEAKING AND REPLACED IT PER AMM 49-52-51. A SATISFACTORY LEAK /OPERATIONAL CHECK WAS ACCOMPLISHED.

More about the Airbus A320-214