AIRCRAFT WAS NOT GROUNDED: SMOKE DETECTOR AURAL ALERT NO FIRE CONFIRMED BUT HEAT FELT ON PANEL ALERT WENT AWAY AFTER 1 MINUTE, 3L-1LC. VISUAL INSPECTION PERFORMED. SMOKE DETECTOR AND THERMAL INDICATION CHECKS NORMAL. PER AMM 26-13-00