Service difficulty report · Smoke Detector · Airbus A300*

Difficulty date
May 29, 2022
Submitted
June 1, 2022
Operation
Air carrier
Aircraft
N580UW
Make and model
Airbus A300*
Aircraft serial
6133
Aircraft time
25,426 hours, 10,023 cycles
Part
Smoke Detector
Condition
False Indication
Location
Zone 900 - Lav/G
Stage of operation
CR
How discovered
V
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS NOT GROUNDED: IN CRUISE FLIGHT GOT ECAM MESSAGE SMOKE LAVATORY SMOKE FOR ABOUT 30 SECONDS. COMPLIED WITH ECAM AND FOLLOW UP PROCEDURES. LEFT AFT LAVATORY CONFIRMED SAFE BY FLIGHT ATTENDANT. NO EVIDENCE, PASSENGER WAS IN LAVATORY WITH ECAM. MAINTENANCE RESET CIRCUIT BREAKERS PER AMM 26-17-00 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.