Service difficulty report · Regulator Valve · Airbus A319132

Difficulty date
July 31, 2022
Submitted
August 4, 2022
Operation
Air carrier
Aircraft
N807AW
Make and model
Airbus A319132
Aircraft serial
1064
Aircraft time
70,400 hours, 32,185 cycles
Part
Regulator Valve
Part number
6714D070000
Part serial
00355
Condition
Faulty
Location
Zone 400 - Nac/P
Part time
89,197 hours, 39,763 cycles
Stage of operation
NR
How discovered
V
Nature of condition
J
Precautionary procedure
A, D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: ENGINE 2 BLEED ABNORMAL PRESSURE ON TAKE OFF. AIRCRAFT AIR INTERRUPTED BACK TO DFW. **SUPPLEMENTAL REPORT FOR AALA202208027557: REMOVED AND REPLACED PRESSURE REGULATING VALVE (AALA202208027557). REMOVED AND REPLACED BLEED MONITORING COMPUTER (AALA202208030799) AND REMOVED AND REPLACED HIGH PRESSURE BLEED VALVE (AALA202208035334). OPERATIONS CHECK GOOD.** (CLOSED)

More about the Airbus A319-132