Service difficulty report · O-Ring · Airbus A300*

Difficulty date
August 26, 2022
Submitted
September 9, 2022
Operation
Air carrier
Aircraft
N723UW
Make and model
Airbus A300*
Aircraft serial
1109
Aircraft time
61,136 hours, 35,993 cycles
Part
O-Ring
Condition
Leaking
Location
Zone 100 - Fuse
Component
Apu · Honeywell · 1319A
Component part number
38007081
Stage of operation
DE
How discovered
O
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: DURING DECENT ODOR OF DIRTY SOCKS/OIL FUME SMELL ON FLIGHT DECK. ODOR WAS NOT PRESENT IN PASSENGER CABIN ACCORDING TO FLIGHT ATTENDANTS. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE APU. **ORIGINAL REPORT WAS ALA202208291146** MAINTENANCE REPLACED APU OIL COOLER, REPLACED APU OIL COOLING FAN O-RINGS (AALA202209094454) AND APU OIL COOLING FAN TRANSFER TUBE (AALA202209096343). A SATISFACTORY LEAK / OPERATIONAL CHECK WAS ACCOMPLISHED WITH NO ODORS BEING NOTED