As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AIRCRAFT IN BASE MAINTENANCE: R1 DOOR EMERGENCY POWER ASSIST SYSTEM (EPAS) FAILS OPERATIONAL TEST. RE-CONNECTED D6202P CONNECTOR AT BRACKET AP0322 AND ACCOMPLISHED SATISFACTORY OPERATIONAL TEST PER WDM 33-51-13, WDM 52-11-13, AND AMM 52-11-20.