What was found
AIRCRAFT WAS GROUNDED: INBOUND FLIGHT ATTENDANT REPORTED ODOR / FUME EVENT DURING LANDING PHASE,. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE APU. **SUPPLEMENTAL REPORT FOR AALA202211101057: MAINTENANCE FOUND THE APU OIL COOLING FAN LEAKING AND REPLACED IT PER AMM 49-52-51. ** (CLOSED)