What was found
AIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL FAULT MESSAGE DISPLAYED DURING CFDS BITE CHECK. MAINTENANCE REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 10WL PER AMM 33-51-38 AND ACCOMPLISHED A SATISFACTORY BITE CHECK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL FAULT MESSAGE DISPLAYED DURING CFDS BITE CHECK. MAINTENANCE REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 10WL PER AMM 33-51-38 AND ACCOMPLISHED A SATISFACTORY BITE CHECK.