Service difficulty report · Valve · Airbus A319112

Difficulty date
June 15, 2023
Submitted
June 19, 2023
Operation
Air carrier
Aircraft
N742PS
Make and model
Airbus A319112
Aircraft serial
1275
Aircraft time
59,810 hours, 37,818 cycles
Part
Valve
Part number
HTE900087
Condition
Stuck
Location
Zone 600 - Rh Wi
Stage of operation
CR
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: RIGHT OUTER TRANSFER VALVE PARTIALLY CLOSED . FUEL NOT TRANSFERING RIGHT OUTER WING TANK. START WITH 1440 STOP SLOW FEEDING AT 800. WENT BACK TO 1000 IN DESCENT 1000 LBS TRAPPED FUEL. REMOVED AND REPLACED RIGHT OUTER FORWARD TRANSFER VALVE PER AMM 28-15-41. OK FOR SERVICE.