What was found
AIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO PHX. RIGHT AFTER THRUST RED ALTITUDE AFTER TAKE OFF GOT AIR ENGINE 2 BLEED ABNORMAL PRESSURE. CREW ACCOMPLISHED ECAM PROCEDURES AND LANDED SAFELY AT PHX WITHOUT FURTHER INCIDEDNT. **SUPPLEMENTAL REPORT FOR AALA202305192367: MAINTENANCE REPLACED THE OVERPRESSURE VALVE 5HA2, THE BLEED PRESSURE REGULATOR VALVE CONTROL SOLENOID / TEMPERATURE LIMITATION THERMOSTAT 10HA2 (AALA202307272150) AND THE BLEED AIR PRECOOLER EXCHANGER (AALA202307272325) ON THE #2 ENGINE. A SATISFACTORY LEAK / OPERATIONAL CHECK WAS ACCOMPLISHED. **(CLOSED)