Service difficulty report · Outflow Valve · Airbus A319115

Difficulty date
September 22, 2023
Submitted
September 25, 2023
Operation
Air carrier
Aircraft
N9018E
Make and model
Airbus A319115
Aircraft serial
6150
Aircraft time
25,526 hours, 11,881 cycles
Part
Outflow Valve
Part number
2079020BA
Part serial
15116485
Condition
Faulted
Location
Zone 100 - Fuse
Stage of operation
CR
How discovered
9
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED INBOUND TO DFW DUE TO CABIN PRESSURE SYSTEM 1 AND 2 FAULT IN FLIGHT 39, 000. THE AIRCRAFT LANDED SAFELY AT DFW WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED VALVE PER AMM 21-31-51 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.

More about the Airbus A319-115