What was found
AIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT FAILED BUILT IN TEST EQUIPMENT TEST. REPLACED EMERGENCY POWER SUPPLY UNIT PER AMM 33-51-38-0401.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT FAILED BUILT IN TEST EQUIPMENT TEST. REPLACED EMERGENCY POWER SUPPLY UNIT PER AMM 33-51-38-0401.