What was found
WHILE ACCOMPLISHING WORK CARD 08C20025006 (DVI-EMERGENCY ESCAPESLIDE AND PRESSURE BOTTLE) FOUND HEAT SHRINK TUBING LOOSE AND INTERFERING WITH GIRT BAR FLOOR ATTACH FITTINGS AT R1 SLIDE. MAINTENANCE REPLACED RED HEAT SHRINK TUBING IAW AARD 25-66-00-4