Service difficulty report · Connector · Airbus A319112

Difficulty date
May 30, 2024
Submitted
June 10, 2024
Operation
Air carrier
Aircraft
N762US
Make and model
Airbus A319112
Aircraft serial
1358
Aircraft time
60,323 hours, 39,273 cycles
Part
Connector
Part number
UNKNOWN
Condition
Inoperative
Location
Fuel Pump
Stage of operation
CR
How discovered
O
Nature of condition
P
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS NOT GROUNDED: LEFT CENTER FUEL TANK PUMP NEVER CAME ON IN CRUISE. PUMP SWITCH WAS ON. CENTER TANK FUEL WAS PUMPED OUT BY THE RIGHT CENTER TANK PUMP. NO ECAM OR ECAM MESSAGES. ON FUEL ECAM PAGE CENTER TANK PUMP INDICATION WAS AMBER AND CLOSED.**SUPPLEMENTAL REPORT FOR AALA202406030470: MAINTENANCE FOUND CENTER TANK PUMP 1 GFI CONNECTOR INOPERATIVE AND REPLACED IT PER ESPM 20-46-50. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLIISHED.** (CLOSED)