What was found
AIRCRAFT IN BASE MAINTENANCE: CORROSION CENTER FITTING AT LEVEL STR 23R BTW FR 66 AND FR 68 AT AFT GALLEY AREA, MEASURES OF CORROSION ARE L=1.408INCH, W=1.570INCH, D=0.080INCH. MAINTENANCE REPLACED CENTER FITTING LOC. ON LOWER SILL AT LEVEL STR 23R BTW FR 66 TO FR 68 RH SIDE IAW A319 SRM 51-42-11-801 AND DWG D53480505.