What was found
AIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR BEAM +Y765 LOCATED BTW FR66 AND FR70 AT AFT GALLEY AREA L=1.100 INCH W=1.020 INCH D=0.058 INCH. MAINTENANCE REPLACED FLOOR BEAM +Y765 LOC BTW FR66 TO FR70 AT LEVEL STRG 23L AT AFT GALLEY AREA IAW A319 SRM 51-42-11-801, A319 SRM 51-72-11-911-001 AND DWG D53478309.