What was found
AIRCRAFT IN BASE MAINTENANCE: ELONGATED HOLE ON SPLICE O/B SIDE LOWER LOC. FLOOR BEAM +Y765 AT LEVEL FR64 AFT GALLEY AREA MEASURE OF ELONGATE HOLE ON SPLICE IS 0.263 INCH. MAINTENANCE REPLACED SPLICE O/B SIDE LOWER AND FASTENERS LOC. FLOOR BEAM Y765 AT LEVEL FR64 AFT GALLEY AREA IAW A319 SRM 51-42-11-801 AND DWG D53472000.