What was found
AIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR BEAM +Y765 LOC. BTW FR64 AND FR65 AT AFT GALLEY AREA MEASURE ARE: L=1.425 INCH, W=1.359 INCH, D=0.002. MAINTENANCE REPLACED FLOOR BEAM Y765 AND FASTENERS LOCATED BTW FR 64 AND FR 66 AT AFT GALLEY AREA AND SPLICES (4E/A), BRACKET (1 E/A) AND HARD POINT (2 E/A) IAW A319 SRM 51-42-11-801 AND DWG D53472035