What was found
AIRCRAFT IN BASE MAINTENANCE: CRACK ON HOLE H1 INSTERCOSTAL FITTING LOC. ON FR 20 LH SIDE AT LEVEL DOOR STOP 7, FWD GALLEY AREA, MEASURE OF CRACK IS L=0.103 IN. MAINTENANCE REPLACED INSTERCOSTAL FITTING LOC. ON FR 20 LH SIDE AT LEVEL DOOR STOP 7, FWD GALLEY AREA I.A.W A319 SRM 53-11-12-300-011, FIG 005, SRM A319 51-72-11-911-001, DWG D53114098, DWG 53925003.