What was found
AIRCRAFT WAS NOT GROUNDED: POWER PORTS AT ROWS 16 AND 17 DEACTIVATED DUE TO ELECTRICAL BURNING ODOR REF MIC 1396210. MAINTENANCE REPLACED POWER OUTLET UNIT AT 16D IAW AMM 25-21-37.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT WAS NOT GROUNDED: POWER PORTS AT ROWS 16 AND 17 DEACTIVATED DUE TO ELECTRICAL BURNING ODOR REF MIC 1396210. MAINTENANCE REPLACED POWER OUTLET UNIT AT 16D IAW AMM 25-21-37.