Service difficulty report · Pump · Airbus A319112

Difficulty date
August 22, 2025
Submitted
August 25, 2025
Operation
Air carrier
Aircraft
N774XF
Make and model
Airbus A319112
Aircraft serial
2019
Aircraft time
66,799 hours, 34,480 cycles
Part
Pump
Condition
Inoperative
Location
Zone 100
Stage of operation
IN
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT WAS GROUNDED: DUE TO EXCESSIVE FUEL IMBALANCE DIVERTED TO KCLT. EMERGENCY DECLARED AIRCRAFT LANDED OVERWEIGHT AND WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT IAW TSM 28-21-00-810-813-A. REPLACED CENTER TANK PUMP 1 FUEL PUMP PRESSURE SWITCH (39QA) IAW AMM 28-21-15.