What was found
AIRCRAFT IN BASE MAINTENANCE: CRACK IN ELECTRICAL GROUND POWER RECEPTACLE SURROUND DOUBLER LOWER CUTOUT IS MISSING FILLER AT BS 222 BETWEEN S20R AND S21R. REPAIRED PER SRM 53-10-15-2R-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIRCRAFT IN BASE MAINTENANCE: CRACK IN ELECTRICAL GROUND POWER RECEPTACLE SURROUND DOUBLER LOWER CUTOUT IS MISSING FILLER AT BS 222 BETWEEN S20R AND S21R. REPAIRED PER SRM 53-10-15-2R-4.