What was found
AIRCRAFT IN BASE MAINTENANCE: DURING EPSU TEST GOT CLASS 1 FAULT FOR ESPU 10WL. PERFORMED T/S AND FOUND 10WL BATTERY INOPERATIVE PER TSM 33-51-00-810-829-A. MAINTENANCE REPLACED AND PERFORMED GOOD OPS CHECK AT 10WL BATTERY EPSU PER AMM 33-51-38-000 / 400-002-A, AMM 33-51-00-820-801-A, AMM 33-51-00-710-001-A, AMM 23-33-00-740-012-A.