What was found
AIRCRAFT IN BASE MAINTENANCE: CORROSION CENTER FITTING BTW FR66 AND FR68 LH SIDE AFT GALLEY MEASURES ARE L=1.302 IN, W=0.383 IN, D=0.220 IN. MAINTENANCE REPLACED CENTER FITTING AND FASTENERS LOCATED BTW FR66 AND FR68 LH SIDE AFT GALLEY AREA I.A.W A319 SRM 51-72-11-911-001, A319 SRM 51-42-11-801 AND DWG D53480505, D53480048.