As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AIRCRAFT NOT GROUNDED. AFTER TAKEOFF GOT INOPERATIVE SYS STATUS MESSAGE FOR CENTER TANK PUMP NR 2 & NO ASSOCIATED ECAM MESSAGE. ON THE FUEL SYS PAGE. PUMP INDICATING AN AMBER LOW PRESSURE. TRIED RECYCLING PUMP & HAD NO CHANGE. THERE WAS NO FUEL IN CENTER TANK. REPLACED THE FUEL PUMP PRESSURE SWITCH 70QA IAW AMM 28-21-15 AND ACCOMPD A SATIS OPS CHK WITH NO FAULTS NOTED.