What was found
AIRCRAFT IN BASE MAINTENANCE: CORROSION CENTER FITTING LOC. LOWER SILL BTW FR66 AND FR68 AT LEVEL S TR23R AT AFT GALLEY AREA, MEASURES ARE: L: 3.170 IN, W: 0.583 IN, D: 0.005 IN. MAINTENANCE REPLACED CENTER FITTING LOC. LOWER SILL BTW FR66 AND FR68 AT LEVEL STR23R AT AFT GALLEY AREA I.A.W A319 SRM 51-42-11-801, A319 SRM 51-72-11-911-001 AND DWG D53480009.