What was found
AFW - FOUND FLOOR BEAM HAS CORROSION BEYOND LIMITS. ALODINED, FILLED WITH BMS 5-92 SEALANT. INSTALLED REPAIR STRAP WET WITH BMS 5095 SEALANT, PRIMED AND PAINTED PER ENGINEERING MRB 767-1025. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND FLOOR BEAM HAS CORROSION BEYOND LIMITS. ALODINED, FILLED WITH BMS 5-92 SEALANT. INSTALLED REPAIR STRAP WET WITH BMS 5095 SEALANT, PRIMED AND PAINTED PER ENGINEERING MRB 767-1025. (M)