What was found
AFW - FOUND FLOOR BEAM CORROSION, REMOVAL BEYOND SRM LIMITS. ALODINE BLENDED AREA. FILL BLEND OUT WITH BMS-592. FABRICATE A REPAIR STRAP FROM .050 301 HALF HARD STAINLESS AND INSTALL WET PER ENGINEERING MRB 767-970.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND FLOOR BEAM CORROSION, REMOVAL BEYOND SRM LIMITS. ALODINE BLENDED AREA. FILL BLEND OUT WITH BMS-592. FABRICATE A REPAIR STRAP FROM .050 301 HALF HARD STAINLESS AND INSTALL WET PER ENGINEERING MRB 767-970.