What was found
AFW - FLOOR BEAM AT STATION 347 RBL 48 TO RBL 78 HAS CORRODED BEYOND SRM LIMITS. BLENDED OUT CORROSION, ALODINED BLENDED AREAS. FILLED WITH BMS 5-92. FABRICATED STAINLESS STRAP. PRIMER COATED AND INSTALLED REPAIR STRAP WET. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FLOOR BEAM AT STATION 347 RBL 48 TO RBL 78 HAS CORRODED BEYOND SRM LIMITS. BLENDED OUT CORROSION, ALODINED BLENDED AREAS. FILLED WITH BMS 5-92. FABRICATED STAINLESS STRAP. PRIMER COATED AND INSTALLED REPAIR STRAP WET. (M)