What was found
AFW - STRINGER CORRODED BEYOND SRM LIMITS. REQUESTED AUTHORIZATION FROM ENGINEERING TO REMOVE 5 INCHES OF STR 36L (1304.5 TO 1299.5) AND EXTEND STR SPLICE AT STA 1307 FORWARD TO STA 1294.5. T.S.T. 40,223.25. CYCLES, 12,808. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - STRINGER CORRODED BEYOND SRM LIMITS. REQUESTED AUTHORIZATION FROM ENGINEERING TO REMOVE 5 INCHES OF STR 36L (1304.5 TO 1299.5) AND EXTEND STR SPLICE AT STA 1307 FORWARD TO STA 1294.5. T.S.T. 40,223.25. CYCLES, 12,808. (X)