As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - REMOVED CORROSION ON FLOOR BEAM. AFTER BLENDING, FOUND BEYOND SRM LIMITS. ALODINED AND BLENDED. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 1/2 HARD STAINLESS STEEL. INSTALLATION APPROVED BY ENGINEERING PER MRB 767-1050. (X)