What was found
AFW - FOUND AND BLENDED CORROSION IN THE UPPER SURFACE OF THE CHORD IN TWO AREAS. THE FWD BLEND-OUT IS WITHIN LIMITS, HOWEVER, DURING ULTRASONIC THICKNESS CHECK, A THICKNESS OF APPROXIMATELY 0.140 INCH WAS INDICATED EVEN THOUGH MINIMAL MATERIAL WAS REMOVED. SUSPECT INTERNAL INCLUSION OR POCKET OF FILLIFORM CORROSION, RUNNING HORIZONTALLY. ALODINED AND PRIMED BLENDED AREAS. APPROVED FOR CONTINUED SERVICE WITH NOTED CONDITION BY ENGINEERING PER MRB 767-1055. PART WILL BE REPLACED AT NEXT MRB NOT TO EXCEED 18 MONTHS FROM 11-3-95, OR 3,000 CYCLES FROM 5,657 CYCLES, WHICHEVER OCCURS FIRST. TST 33,946.03. CYCLES, 6,219. (X)