What was found
AFW - FLOOR BEAM HAS CORROSION ON UPPER SURFACE. ALODINED BLENDED AREA, FILLED BLENDOUT. FABRICATED AND INSTALLED REPAIR STRAP WING .050 INCH 301.5 HARD STAINLESS STEEL. APPLIED PRIMER, APPROVED BY ENGINEERING AND ACCOMPLISHED PER MRB 767-1073. (M)