What was found
DFW - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS IN FIRST CLASS INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT ROW 5 AND 6. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DFW - DURING OVERNIGHT CHECK, FOUND THE EMERGENCY EXIT FLOOR PATH LIGHTS IN FIRST CLASS INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP AT ROW 5 AND 6. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)