What was found
AFW - FOUND FLOOR BEAM LOWER FLANGE AND BOTTOM OF WEB ARE DENTED. INSTALLED 0.080 BY 2.5 BY 13 INCH 7075-0 REPAIR ANGLE PER ENGINEERING MRB 767-1025. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFW - FOUND FLOOR BEAM LOWER FLANGE AND BOTTOM OF WEB ARE DENTED. INSTALLED 0.080 BY 2.5 BY 13 INCH 7075-0 REPAIR ANGLE PER ENGINEERING MRB 767-1025. (M)