What was found
TUL - CORROSION ON FWD SIDE OF FRAME, 4 INCHES TO THE RIGHT OF LONGERON 30 AND 2 INCHES ABOVE INTERIOR SKIN. SPLICED IN NEW SECTION OF FWD WEB LAYER, REF SRM 53-01, FIGURE 2. TST: 34,543.23 HRS. CYCLES, 19,744. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - CORROSION ON FWD SIDE OF FRAME, 4 INCHES TO THE RIGHT OF LONGERON 30 AND 2 INCHES ABOVE INTERIOR SKIN. SPLICED IN NEW SECTION OF FWD WEB LAYER, REF SRM 53-01, FIGURE 2. TST: 34,543.23 HRS. CYCLES, 19,744. (X)