What was found
TUL - CRACK IN FRAME WEB, STA 825.95, LT STR 16 CUT-OUT. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 51-40-2, PAGES 1-8, AND SRM 51-40, PAGE 1. TST: 62,953 HRS. CYCLES: 41,811. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - CRACK IN FRAME WEB, STA 825.95, LT STR 16 CUT-OUT. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 51-40-2, PAGES 1-8, AND SRM 51-40, PAGE 1. TST: 62,953 HRS. CYCLES: 41,811. (X)