What was found
TUL - FOUND FLOORBOARD T-ANGLE CORRODED AT JOGGLE AT FLOORBEAM 15A. CUT OUT CORRODED SECTION AND REPLACED WITH FILLER PIECE ON TOP AND TWO STRAPS UNDERNEATH ONE ON EACH SIDE. REPLACED RIVETS WITH APPROPRIATE HI-LOCKS. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND FLOORBOARD T-ANGLE CORRODED AT JOGGLE AT FLOORBEAM 15A. CUT OUT CORRODED SECTION AND REPLACED WITH FILLER PIECE ON TOP AND TWO STRAPS UNDERNEATH ONE ON EACH SIDE. REPLACED RIVETS WITH APPROPRIATE HI-LOCKS. (M)