What was found
TUL - FOUND 3 AREAS OF CORROSION AROUND CLIP NUT HOLES FOR FLOORBOARDS, ONE AREA BLENDED BEYOND LIMITS. REMOVED AND REPLACED WITH A NEW SECTION OF 'L' ANGLE PER SRM 51-72-10 PAGE 1 AND PAGE 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TUL - FOUND 3 AREAS OF CORROSION AROUND CLIP NUT HOLES FOR FLOORBOARDS, ONE AREA BLENDED BEYOND LIMITS. REMOVED AND REPLACED WITH A NEW SECTION OF 'L' ANGLE PER SRM 51-72-10 PAGE 1 AND PAGE 2. (M)